Cryogenic valves
Selecting a cryogenic valve
How the seat, stem packing, bonnet and cavity relief work together. Follow one LNG isolation duty from the sectional drawing to the cold-test report.

BMT describes a helium seat-closure test and a separate shell-leak test at this temperature. Each answers a different question. Neither sets the design limit of another valve.
Seat, gasket & packing
Read the three sealing locations
A closed valve may pass fluid downstream while its exterior stays dry. A stem can leak to atmosphere while the valve still isolates. The sectional drawing tells you which interface a leakage requirement actually covers.

Read the bill of materials alongside the section
The ball seat forms the shut-off line. The stem packing surrounds a moving stem. A static gasket closes a pressure-boundary joint. A single entry called “seal material” leaves two of those decisions unspecified.
| Location | BMT material shown | Specify or verify |
|---|---|---|
| Ball seat · item 5 | PCTFE | Required seat leak rate, test medium, cold differential and permitted isolation direction. |
| Static gasket · item 12 | Graphite with 316 stainless steel | Joint configuration, material identity and external tightness over the thermal cycle. |
| Stem packing · item 16 | Graphite | External leakage criterion during or after movement, packing temperature and available operating torque. |
The two- and three-piece illustration on the next catalogue page has a different construction, including a PCTFE bonnet seal. Carry the selected drawing and its revision into the valve data sheet.
Trapped liquid
Which way can this valve isolate?
A closed ball can leave liquid in the body cavity. As the liquid warms, pressure can rise within that small volume. The cavity design determines where it can discharge and may determine the permitted isolation direction.
| Arrangement | Implication for the drawing |
|---|---|
| A relief hole in the ball connects the cavity to the designated upstream side. | BMT describes this design as unidirectional. Mark the required pressure side for shut-off, confirm it on the approved drawing and match it to the body marking. |
| A separate cavity relief valve is fitted. | Confirm where the cavity vents, which side can stay pressurised and whether isolation is permitted in each direction. State the expected reverse differential during shutdown. |
| Self-relieving seats provide the cavity path. | Confirm which seat relieves, where pressure goes and which seat maintains isolation under the stated differential. Bidirectional service depends on the exact design. |
The valve’s cavity relief feature serves its internal volume. Identify each liquid-filled pipe section between closed valves separately and provide thermal overpressure protection where the piping design requires it.
Construction & access
Choose the seat and body for the duty
Low temperature can change dimensions and seat contact as metal and nonmetal parts contract. Repeated operation adds wear. Set the required operating and leakage performance before selecting the seat material or entry style.
| Design detail | What makes the choice defensible |
|---|---|
| Soft or metal seat | A PCTFE seat is documented for the illustrated BMT valve. Solids or erosive duty can justify evaluating a metal seat. Specify the achievable leak rate at the stated differential and temperature for the actual seat design. |
| Extended bonnet and stem | The extension separates the packing from the cold body. Agree on mounting orientation, insulation termination, available height and access to the gland with the manufacturer. |
| Top-entry or split-body | Top entry can allow internal access from above when there is removal space and the design supports it. A split body has different joint and removal requirements. Check dismantling clearance against the installed pipework. |
| Bore, ends and actuator | Check actual port and pressure loss, flange or weld-end details, face-to-face length, and actuator breakaway torque at maximum specified differential and minimum temperature. Confirm the demanded fail position. |
A flange class is a designation with pressure–temperature ratings tied to materials and standards. For a specific assembly, verify the valve’s complete rating and the lower limiting part across the duty envelope.
Evidence & testing
What should the cold-test report prove?
For an LNG isolation valve, define two events before reviewing any certificate. The valve must hold the specified differential when cold, and its pressure boundary must stay tight as the assembly cools, operates and warms again.

Three different observations
Seat leakage measures flow through the closed valve. Shell leakage concerns release across the pressure boundary. Torque measurements show whether the valve can move under the stated test conditions. An external packing-emissions requirement needs its own acceptance basis.
Type evidence
ISO 28921-2 addresses type testing. Check the representative valve’s design, size, class, material, seat, direction and how far the evidence extends to the valve being purchased.
Production evidence
ISO 28921-1 covers design, manufacture and production testing in its scope from −50 °C down to −196 °C. Agree which results must identify the supplied serial number. Record test medium, metal temperature, applied differential and direction, permitted leak rate and measured result.
For the worked LNG duty, release the valve specification when the seat and external leak criteria, approved isolation arrow, cavity relief route, cold operating torque and applicable test report all point to the same configuration.